Stanford Research Systems - IGC100 Vacuum Gauge Controller
Specifications
Operation

Pressure range
1000 Torr to UHV (<10-11)

Compatible gauges
Bayard-Alpert type ionization gauges, convection-enhanced Pirani gauges, capacitance manometers (0 to 10 VDC linear output)

Display

Type
Back-lit, touchscreen LCD (4.7")

Resolution
320 ? 240 pixels

Modes
Numeric, bar graph, P vs. T

Units
Torr, mbar, bar, Pa and micron

Numeric resolution
3-digit mantissa plus exponent

Update rate
2 samples per second

Dual Pirani gauge
Simultaneous readout of two Pirani gauges (std.)

Dual ion gauge
Sequential readout of a second ion gauge (opt.)

Auto-Start
Use PG1 or PG2 to automatically turn IG1 or IG2 on/off when pressure goes through user-defined level.

Electrical (20 ?C to 30 ?C)
Electron emission current

Range
10 ?A to 12 mA

Stabilization
Electronically controlled

Accuracy
?1 % of setting

Anode

Potential
+180 VDC

Accuracy
?0.3 % of setting

Filament

Potential
+30 VDC

Accuracy
?0.3 % of setting

Filament power (max.)
7 ADC, 7 VDC

Degas

Mode
Electron bombardment

Power
1 to 75 W, adjusted in 1 watt steps

Time
1 to 30 minute, adjusted in 1 minute steps

Anode potential
500 VDC

Emission current
2 to 150 mA

Display
Approxmate pressure, degas power and remaining time

Electrometer

Accuracy
1 % of reading

Zero drift
0.4 pA

Analog I/O

Ports
4 configurable analog ports

Range
?12 VDC

Resolution
14-bit (In), 12-bit (Out)

Update rate
2 Hz

Connector
BNC

Vacuum Ionization Gauge
Gauge type
Bayard-Alpert type ionization gauges including glass tubulated (std. and broad-range), nude, nude-UHV, STABIL_ION?, MICRO_ION?. Supports tungsten and thoriated-iridium filaments.

Pressure range
10-11 to 10-1 Torr

Lower limit
X-ray limit of Bayard-Alpert gauge

Upper limit
Maximum operating pressure specified by gauge manufacturer

Pressure calculation
From sensitivity constant or full range calibration curve

Sensitivity constant
0.1/Torr to 100/Torr

Filament selection
Fil 1, Fil 2, or both

Overpressure protection
Programmable trip points, auto-start protection

Analog output
Log, 1 V/decade, 1 to 10 V w/ fault and off indication

Convection-Enhanced Pirani Gauge
Gauge type
PG105U convection-enhanced Pirani gauges, CONVECTRON? and HPSTM Series 317 convection-enhanced Pirani gauges.

Pressure range
999 to 10-3 Torr. Lower pressure limit extends to 10-4 Torr w/ zero adjustment.

Gas type calibration
Direct readings for air, N2 and Ar. Menu driven zero and atmospheric adjustments.

Analog output
Log, 1V/decade, 1 to 8 V

Capacitance Manometer
Number of gauges
Simultaneous readout of up to four capacitance manometers using the auxiliary inputs.

Auxiliary power output
?15 VDC, 100 mA (for CM power)

Process Control (opt.)
Number of channels
8 channels with programmable setpoint, polarity, hysteresis, delay, audio signal and text messages. All channels can be manually operated from front panel.

Process variables
Pressure (any gauge), voltage (I/O ports), time (internal clock), TTL and gauge status.

Relays
8 relays, SPDT, form C, 5A/250VAC/30VDC, resistive load

TTL control
8 TTL inputs and 8 TTL outputs (active low, opto-isolated) corresponding to relays

Additional inputs
12 opto-isolated TTL inputs corresponding to: Remote Enable, IG1 on/off, IG2 on/off, Degas on/off, Fil 1/Fil 2 select, both Fil select, IG lockout, IG Control keypad lockout, PG1 on/off, PG2 on/off, data logging time reset, touchscreen enable/disable

General
Interfaces
RS-232 (std.), GPIB and Ethernet interface with embedded web-server hardware (opt.)

Power
90 to 264 VAC, 47 to 63 Hz, 240 W

Operating temperature
0 ?C to 40 ?C, non-condensing

Weight / dimensions
15 lbs., 8.5" ? 5.25" ? 16" (WHL)

Warranty
One year parts and labor on defects in materials and workmanship